Siemens MP377 12" Touch
6AV6 644-0AA01-2AX0
Pre Owned
| General information | ||
| Product type designation | MP377 12" touch | |
| Customer-specific configuration | No | |
| Display | ||
| Design of display | TFT | |
| Screen diagonal | 12.1 in | |
| Color display | Yes | |
| Number of colors | 65 536 | |
| Resolution (pixels) | ||
| ● Horizontal image resolution | 800 pixel | |
| ● Vertical image resolution | 600 pixel | |
| Backlighting | ||
| ● MTBF backlighting (at 25 °C) | 50 000 h | |
| Control elements | ||
| Control elements | Touch screen | |
| Keyboard fonts | ||
| ● Function keys | ||
| — Number of function keys | 0 | |
| — Number of function keys with LEDs | 0 | |
| ● System keys | No | |
| — Number of system keys | 0 | |
| ● Numeric keyboard | Yes | |
| ● alphanumeric keyboard | Yes | |
| ● hexadecimal keyboard | Yes | |
| Touch operation | ||
| ● Design as touch screen | Yes; analog, resistive | |
| Connection type | ||
| ● Type of connection for mouse/keyboard/barcode reader | USB / USB / USB | |
| Installation type/mounting | ||
| maximum permissible angle of inclination without external ventilation | 35° | |
| Supply voltage | ||
| Type of supply voltage | DC | |
| Input current | ||
| Current consumption (rated value) | 1.5 A | |
| Power | ||
| Active power input, typ. | 36 W | |
| Memory | ||
| Type of memory | Flash / RAM | |
| Memory available for user data | 12 288 kbyte | |
| Time of day | ||
| Clock | ||
| ● Type | Hardware clock, battery backup, synchronizable | |
| ● retentive | Yes | |
| ● synchronizable | Yes | |
| Interfaces | ||
| Interfaces/bus type | 1x RS 422, 1x RS 485, 2x Ethernet (RJ45) | |
| Number of industrial Ethernet interfaces | 2 | |
| Number of RS 485 interfaces | 1 | |
| Number of RS 422 interfaces | 1 | |
| Number of USB interfaces | 2; Up to 1 GB respectively | |
| CF card slot | 1x CF card slot | |
| Multimedia card/SD card slot | 1x Multimedia Card slot, up to 128 MB | |
| With software interfaces | No | |
| Protocols | ||
| Supports protocol for PROFINET IO | Yes | |
| PROFIsafe | No | |
| PROFIBUS | Yes | |
| EtherNet/IP | Yes | |
| MPI | Yes | |
| Protocols (Ethernet) | ||
| ● TCP/IP | Yes | |
| Protocols (terminal link) | ||
| ● Sm@rtServer | Yes | |
| Further protocols | ||
| ● MODBUS | Yes | |
| ● other bus systems | Yes | |
| EMC | ||
| Emission of radio interference acc. to EN 55 011 | ||
| ● Limit class A, for use in industrial areas | Yes | |
| Degree and class of protection | ||
| IP (at the front) | IP65 | |
| IP (rear) | IP20 | |
| NEMA (front) | NEMA 4, NEMA 12 (when installed) | |
| Standards, approvals, certificates | ||
| CE mark | Yes | |
| UL approval | Yes | |
| cULus | Yes | |
| Suitable for safety functions | No | |
| Use in hazardous areas | ||
| ● ATEX Zone 2 | No; certificate no longer available as of 1 October 2020 | |
| ● ATEX Zone 22 | No; certificate no longer available as of 1 October 2020 | |
| ● FM Class I Division 2 | Yes | |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● min. | 0 °C | |
| ● max. | 50 °C | |
| Ambient temperature during storage/transportation | ||
| ● min. | -20 °C | |
| ● max. | 60 °C | |
| Relative humidity | ||
| ● Operation, max. | 90 % | |
| Operating systems | ||
| pre-installed operating system | Windows CE | |
| configuration / header | ||
| Message indicator | Yes | |
| Alarm system (incl. buffer and acknowledgment) | Yes | |
| Process value display (output) | Yes | |
| Process value default (input) possible | Yes | |
| Recipe management | Yes | |
| Configuration software | ||
| ● Configuration tool | WinCC flexible Standard Version 2007 or higher (to be ordered separately) | |
| ● STEP 7 Basic (TIA Portal) | No | |
| ● STEP 7 Professional (TIA Portal) | No | |
| ● WinCC flexible Compact | No | |
| ● WinCC flexible Standard | Yes | |
| ● WinCC flexible Advanced | Yes | |
| ● WinCC Basic (TIA Portal) | No | |
| ● WinCC Comfort (TIA Portal) | Yes | |
| ● WinCC Advanced (TIA Portal) | Yes | |
| ● WinCC Professional (TIA Portal) | Yes | |
| Languages | ||
| Online languages | ||
| ● Number of online/runtime languages | 16 | |
| Project languages | ||
| ● Languages per project | 32 | |
| Functionality under WinCC (TIA Portal) | ||
| Libraries | Yes | |
| Task planner | Yes | |
| Help system | Yes | |
| ● Number of characters per info text | 70 | |
| Message system | ||
| ● Number of alarm classes | 32 | |
| ● Number of messages | 4 000 | |
| ● Bit messages | Yes | |
| — Number of bit messages | 4 000 | |
| ● Analog messages | Yes | |
| — Number of analog messages | 200 | |
| ● Telegram message procedure Alarm S | Yes | |
| ● System messages HMI | Yes | |
| ● System messages PLC | Yes | |
| ● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) | Yes | |
| ● Lines | 1 | |
| ● Number of characters per message | 80 | |
| ● Number of process values per message | 8 | |
| ● Message indicator | Yes | |
| ● First/last value | Yes | |
| Recipe management | ||
| ● Number of recipes | 500 | |
| ● Data records per recipe | 1 000 | |
| ● Entries per data record | 1 000 | |
| ● Recipe memory | 128 KB integrated Flash, expandable | |
| Variables | ||
| ● Number of variables per device | 4 096; Configuration with WinCC flexible 2008 and higher | |
| ● Number of variables per screen | 400 | |
| ● Number of variables | 2 000 | |
| ● Initial values | 2 048 | |
| ● Type Date & Time | 2 048 | |
| ● Limit values | Yes | |
| ● Multiplexing | Yes | |
| ● Structures | Yes | |
| Images | ||
| ● Number of configurable images | 500 | |
| ● Permanent window/default | Yes | |
| ● Start screen configurable | Yes | |
| ● Image selection by PLC | Yes | |
| ● Image number in the PLC | Yes | |
| Image objects | ||
| ● Text objects | 30 000 text elements | |
| ● Number of I/O fields per image | 400 | |
| ● Number of date/time fields | 400 | |
| ● Return | Yes | |
| ● Graphics object | Bit maps, icons, vector graphics | |
| — Icons | 2 000 | |
| Complex image objects | ||
| ● Status/control | With SIMATIC S7 | |
| ● dynamic objects | Diagrams, bar graphs, sliders, analog display, invisible buttons | |
| — Number of objects per project | 2 000 | |
| — Number of curve diagrams per image | 20 | |
| ● Methods | Trend / profile | |
| ● Bar graphs | ||
| — Number of bars per chart | 20 | |
| ● Sliders | ||
| — Number of slides per image | 20 | |
| ● Pointer instruments | ||
| — Number of analog indicators per image | 20 | |
| ● Limit value lines | Yes | |
| ● Number of alphanumerical fields | 300 | |
| — alphanumeric fields per image | 400 | |
| ● Number of numerical fields | 2 048 | |
| — numerical fields per image | 400 | |
| ● Number of password fields | 2 048 | |
| ● Number of visible switches per project | 400 | |
| — visible switches per image | 400 | |
| — hidden switches per image | 400 | |
| ● Number of status switches per project | 400 | |
| — Number of status switches per image | 400 | |
| ● Number of selector switches per project | 400 | |
| — Selector switches per image | 400 | |
| ● Number of signal lamps per project | 400 | |
| — Signal lamps per image | 400 | |
| Attributes for dynamic objects | ||
| ● Color change | Yes | |
| ● X/Y movement | Yes | |
| ● Hide | Yes | |
| Lists | ||
| ● Number of text lists per project | 500 | |
| ● Number of text lists per image | 400 | |
| ● Number of entries per text list | 256 | |
| ● Number of graphics lists per project | 500 | |
| ● Number of graphic lists per image | 400 | |
| ● Number of entries per graphics list | 256 | |
| Archiving | ||
| ● Number of archives per device | 50 | |
| ● Number of measuring points per project | 50 | |
| ● Number of entries per archive | 50 000 | |
| ● Message archive | Yes | |
| ● Process value archive | Yes | |
| ● Archiving methods | Sequential log, circular log, alarm log, process value archive | |
| — Sequential archive | Yes | |
| — Short-term archive | Yes | |
| ● Memory location | CF card, SD/MMC card, Ethernet, USB memory stick | |
| — CF card | Yes | |
| — Ethernet | Yes | |
| ● Data storage format | CSV file, readable, e.g. with MS Excel, MS Access | |
| — CSV | Yes | |
| ● external evaluation | readable, e.g. with MS Excel, MS Access, etc. | |
| ● Size of archive | depending on free memory on ext. card/stick or on free hard disk space via network drive | |
| ● Online evaluation | via trends | |
| — using trend curves | Yes | |
| Filters | ||
| ● cyclic | Yes | |
| ● Tolerance | Yes | |
| ● Change | Yes | |
| Security | ||
| ● Number of user groups | 50 | |
| ● Number of user rights | 32 | |
| ● Password export/import | Yes | |
| Data carrier support | ||
| ● CF card | Yes | |
| ● Hard disk | Yes | |
| Logging through printer | ||
| ● Recording/Printing | Alarms, report (shift report), color print, hardcopy | |
| Transfer (upload/download) | ||
| ● Transfer of configuration | MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition | |
| Process coupling | ||
| ● Connection to controller | S5, S7-200, S7-300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" | |
| ● S7-1200 | Yes | |
| ● S7-1500 | Yes | |
| ● S7-200 | Yes | |
| — PPI (point-to-point) | Yes | |
| — PPI network | Yes | |
| — MPI | Yes | |
| — PROFIBUS DP | Yes | |
| ● S7-300/400 | Yes | |
| — MPI | Yes | |
| — PROFIBUS DP | Yes | |
| — PROFINET | Yes | |
| ● S5 | Yes | |
| — PROFIBUS DP | Yes | |
| ● TI 505 | Yes | |
| ● Allen Bradley (DF1) | Yes | |
| ● Allen Bradley (DF485) | Yes | |
| ● Mitsubishi (FX) | Yes | |
| ● Mitsubishi (MP4) | Yes | |
| ● Telemecanique (Uni-Telway) | Yes | |
| ● OMRON (LINK/Multilink) | Yes | |
| ● Modicon (Modbus) | Yes | |
| ● GE-Fanuc (SNP) | Yes | |
| Functions | ||
| ● TAB sequence | Yes | |
| ● Calculating functions | Yes | |
| ● Animate | Yes | |
| Service tools/configuration aids | ||
| ● Clean screen | Yes | |
| ● Touch calibration | Yes | |
| ● Backup/Restore manually | Yes | |
| ● Simulation | Yes | |
| ● Device switchover | Yes | |
| ● Delta transfer | Yes | |
| Expandability/openness | ||
| ● Open Platform Program | Yes | |
| Peripherals/Options | ||
| Peripherals | Printer, card reader, barcode reader | |
| SIMATIC HMI MM memory card: Multi Media Card | Yes | |
| SIMATIC HMI SD memory card: Secure Digital memory card | Yes | |
| USB memory | Yes | |
| Additional software components loadable | Yes | |
| Dimensions | ||
| Width of the housing front | 335 mm | |
| Height of housing front | 275 mm | |
| Mounting cutout, width | 310 mm | |
| Mounting cutout, height | 248 mm | |
| Overall depth | 72 mm | |
| Weights | ||
| Weight (without packaging) | 3.8 kg | |
| last modified: | 9/6/2023 | |